A VIQUA Arros 9 whole-home UV system pre-mounted on one bracket with a sediment filter housing. Rated at 9 gpm at VIQUA's 30 mJ/cm² dose.

Get a quote for your home

Every system is sized to your water and quoted after a free water test, including installation.

Not sure this is the right system? Book a free water test.

Downloads: Spec sheet (PDF) · Brochure (PDF) · Owner's manual (PDF)

Already own one?

Replacement parts for this system ship free on orders of $100 or more.

About this system

The VIQUA Arros 9-IHS10 combines an Arros 9 ultraviolet (UV) disinfection system with pre-filtration on a single wall-mounted bracket. A 10 in. housing holds a CMB-510-HF sediment cartridge, so the water is filtered before it reaches the UV chamber.

The sediment cartridge traps sand, silt and rust that would otherwise shade microorganisms from the UV light. In the UV chamber a high-output lamp inactivates microorganisms including Cryptosporidium, Giardia and E. coli without adding anything to the water.

The system is rated at 9 gpm (34.1 lpm; 2.0 m³/hr) at VIQUA’s 30 mJ/cm² standard dose and 7 gpm (26.5 lpm; 1.59 m³/hr) at the 40 mJ/cm² NSF/EPA dose, measured at end of lamp life. The inlet is 1 in. FNPT and the outlet is a combo 1 in. MNPT / 3/4 in. FNPT port.

Maintenance is a once-a-year VA09LU lamp unit change, prompted by the touchscreen controller, plus filter cartridge changes about three to four times a year depending on water quality. A pressure-release button and a sump wrench make cartridge changes simple.

Okanagan Aquatech installs and services this system, including water testing to confirm the right configuration for your home.

Features

  • Arros UV chamber and filter housings pre-mounted on one bracket
  • CMB-510-HF sediment cartridge included
  • Pressure-release button on the filter head
  • Chamber-mounted controller with LCD touchscreen
  • One-piece lamp unit with built-in lamp-life tracking (Stream technology)
  • PolyProtect shield allows direct connection to PEX
  • Sump wrench WR40-50 and housing O-ring OR40-50W listed as system components

Specifications

Flow rate at 30 mJ/cm² (VIQUA standard) 9 gpm (34.1 lpm; 2.0 m³/hr)
Flow rate at 40 mJ/cm² (NSF/EPA dose) 7 gpm (26.5 lpm; 1.59 m³/hr)
Flow rate at 16 mJ/cm² (US Public Health dose) 17 gpm (64.3 lpm; 3.86 m³/hr)
Rating basis At 95% UV transmittance, end of lamp life
UV chamber 11.2 in. × 4.0 in. (28.4 cm × 10.16 cm), 304 stainless steel
Controller VA-CTRL, LCD touchscreen, mounted on the chamber; 10.5 in. × 5.0 in. × 6.5 in. (26.67 cm × 12.7 cm × 16.51 cm)
Lamp VA09LU high-output lamp unit (lamp sealed in a fused quartz sleeve), 25 W, rated about 9,000 hours
Pre-filter housings One 10 in. three-piece filter housing (VIQUA “premium three-piece” housings)
Sediment cartridge CMB-510-HF high-flow sediment cartridge, 4.5 in. × 10 in., 5 micron inner / 15 micron outer, max 18 gpm
Inlet port 1 in. FNPT
Outlet port Combo: 1 in. MNPT / 3/4 in. FNPT (3/4 in. MNPT on units built before September 23, 2024)
Overall dimensions (L × H × D) 16.95 in. × 17.5 in. × 9.0 in. (43.0 cm × 44.5 cm × 22.9 cm)
Shipping weight 40 lb (18.1 kg)
Electrical 100–240 V, 50/60 Hz, 1.5 A max; 35 W power consumption
Maximum operating pressure 100 psi (6.9 bar)
Water temperature 2–40 °C (36–104 °F)
Displays Lamp replacement reminder, visual lamp life, true lamp running time, total system running time
Recommended water quality Hardness under 7 gpg (120 mg/L), iron under 0.3 mg/L, manganese under 0.05 mg/L, tannins under 0.1 mg/L, turbidity under 1 NTU, UV transmittance over 75%
Validation Validated by microbial testing for UV dose delivery to inactivate Cryptosporidium, Giardia, E. coli and fecal coliform (VIQUA)
Warranty VIQUA limited warranty: 10 years on the UV chamber, 5 years on the controller and hardware, 1 year on the lamp unit (owner’s manual)

Maintenance

Replace the VA09LU lamp unit once a year, when the controller alerts (about 9,000 hours). The lamp and quartz sleeve are a single part, so there is no separate sleeve to buy. VIQUA recommends cleaning the quartz with a mild acid such as CLR or vinegar during lamp changes and softening the water if hardness is over 7 gpg. Change the filter cartridge about three to four times a year depending on water quality and use; a gradual drop in water pressure means they are due.

Replacement parts

  • VA09LU – replacement UV lamp unit (lamp and quartz sleeve in one piece)
  • VA-CTRL – controller for all Arros systems
  • 411173-R – lamp head O-ring
  • 411111-R – drain plug
  • 411138-R – drain plug O-ring
  • 411203-R – optional splash guard
  • CMB-510-HF – sediment cartridge
  • OR40-50W – filter housing O-ring
  • WR40-50 – sump wrench
  • 420619-R – mounting bracket clamp
  • 260251-R – controller power cord (120 V models)