Ecomix is a blend of ion exchange and sorption media made by Ecosoft. In one tank it softens water and reduces iron, manganese and ammonium and the A and C grades also reduce natural organic matter such as colour and tannins. The components settle into separate layers during the first regeneration.
Iron and manganese are captured by FerroSorb, Ecosoft’s sorption material and washed out during backwash. Organics are taken up by HumiSorb and released with the brine. The system regenerates with ordinary salt using the same backwash, brine and rinse steps as a standard softener, so no oxidizing chemicals or air injection are needed ahead of it.
Ecosoft makes three grades. Ecomix P suits well or tap water with low organic matter and stable quality. Ecomix A handles moderate organics and seasonal changes in the water. Ecomix C handles high organic matter and larger swings in raw water quality. All three are rated for up to 750 ppm hardness, 15 mg/L iron, 3 mg/L manganese and 4 mg/L ammonium. Ecomix A and C carry the WQA Gold Seal to NSF/ANSI 44, 61 and 372.
Ecomix is intended for well and municipal water that is already microbiologically safe, rather than surface water. Okanagan Aquatech tests your water, picks the grade and tank size and installs and services the system.
Features
- Softens and reduces iron, manganese and ammonium in one tank
- A and C grades also reduce colour, tannins and other natural organics
- Regenerates with salt using standard softener cycles
- No oxidizing pre-treatment needed
- Media service life of 3 to 5 years depending on grade
- Ecomix A and C certified by WQA to NSF/ANSI 44, 61 and 372
Specifications
| Grades | Ecomix P (low organic matter, stable water); Ecomix A (moderate organics, seasonal variation); Ecomix C (high organics, large variation) |
|---|---|
| Maximum hardness | 750 ppm as CaCO3 (all grades) |
| Maximum iron | 15 mg/L (all grades) |
| Maximum manganese | 3 mg/L (all grades) |
| Maximum ammonium | 4 mg/L (all grades) |
| Chemical oxygen demand (organics) | P: 3 mg/L O2; A: 20 mg/L, reduced by 50%; C: 20 mg/L, reduced by 80% |
| Dynamic exchange capacity | P: 40 g/L as CaCO3; A: 35 g/L; C: 30 g/L |
| Service life | P: 3 years; A and C: 5 years |
| Service flow rate | 20–25 m/h (bed velocity) |
| Backwash flow rate | 10–15 m/h (lower rates reduce iron removal) |
| Brine (slow rinse) flow rate | 3–5 m/h |
| Bed depth | 500 mm minimum; 800 mm recommended |
| Freeboard | 40% or more (backwash may be poor if media fills more than 60% of the vessel) |
| Salt consumption | 100 g/L of media (150 g/L if using potassium chloride) |
| Brine concentration | 8–10% NaCl |
| Water per regeneration | Under 10 L per litre of media |
| Operating temperature | A and C: 0–40 °C; P: 5–40 °C |
| pH range | A and C: 5–10; P: 5–9 |
| Bead size / bulk density | 0.3–4.0 mm / 0.8 kg/L |
| Packaging | 12 L and 25 L bags |
| Certifications | WQA Gold Seal to NSF/ANSI 44, NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372 for Ecomix A and Ecomix C (certified Sept 23, 2025) |
Maintenance
Keep salt in the brine tank. Ecosoft rates media service life at 3 years for Ecomix P and 5 years for Ecomix A and C. Ecosoft advises against resin cleaners or harsh regeneration aids, which reduce Ecomix efficiency and against oxidative pre-treatment before the system.
Replacement parts
- Ecomix P, A or C media in 12 L or 25 L bags